Command Manual - System Management
Quidway S2000 Series Ethernet Switches Chapter 6 RMON Configuration Commands
6-8
View
System view
Parameter
entry-number: Number of the entry to be added/deleted, ranging from 1 to 65535.
alarm-variable: Specifies the alarm variable with a character string, ranging from 1 to
256, in the OID dotted format, like 1.3.6.1.2.1.2.1.10.1 (or ifInOctets.1).
sampling-time: Specifies the sampling interval, ranging from 5 to 65535 (measured in
seconds).
delta: Sampling type is delta.
absolute: Sampling type is absolute.
rising-threshold threshold-value1: Rising threshold, ranging from 0 to 2147483647.
event-entry1: Event number corresponding to the upper limit of threshold, ranging from
0 to 65535.
falling-threshold threshold-value2: Falling threshold, ranging from 0 to 2147483647.
event-entry2: Event number corresponding to the falling threshold, ranging from 0 to
65535.
owner text: Specifies the creator of the alarm. Length of the character string ranges
from 1 to 127.
Description
Using rmon alarm command, you can add an entry to the alarm table. Using undo
rmon alarm command, you can cancel an entry from this table.
In this way, the alarm event can be triggered in the abnormal situations and then
decides to log and send trap to the NM station.
Example
# Delete the information of entry 15 from the alarm table.
[Quidway] undo rmon alarm 15

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S2000 Series and is the answer not in the manual?

Huawei Quidway S2000 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S2000 Series
CategorySwitch
LanguageEnglish

Related product manuals