Operation Manual - Port
Quidway S6500 Series Ethernet Switches Chapter 1 Ethernet Port Configuration
Huawei Technologies Proprietary
1-11
Table 1-16 Copy port configuration to other ports
Operation Command
Copy port configuration
to other ports
copy configuration source { interface-type
interface-number | interface-name | aggregation-group
agg-id } destination { interface_list
[ aggregation-group agg-id ] | aggregation-group
agg-id }
Note that if the copy source is an aggregation group, take the port with minimum ID as
the source; if the copy destination is an aggregation group, make the configurations of
all group member ports identical with that of the source.
1.2.16 Set Loopback Detection for the Ethernet Port
The following commands are used for enabling the port loopback detection and setting
detection interval for the external loopback condition of each port. If there is a loopback
port found, the switch will put it under control.
Other correlative configurations function only when port loopback detection is enabled
in system view.
Perform the following configuration in corresponding view.
Table 1-17 Set loopback detection for the Ethernet port
Operation Command
Enable loopback detection on the port (System
view/Ethernet port view)
loopback-detection
enable
Disable loopback detection on the port (System
view/Ethernet port view)
undo loopback-detection
enable
Enable the loopback controlled function of the trunk
and hybrid ports (Ethernet port view)
loopback-detection
control enable
Disable the loopback controlled function of the trunk
and hybrid ports (Ethernet port view)
undo loopback-detection
control enable
Set the external loopback detection interval of the
port (System view)
loopback-detection
interval-time time
Restore the default external loopback detection
interval of the port (System view)
undo loopback-detection
interval-time