Operation Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-14
Table 4-19 Turn on/off the information synchronization switch in Fabric
Device Configuration Default value
Configuration
description
Enable
info-center
By default, info-center
is enabled.
Other configurations are
valid only if the info-center
is enabled.
Switch
Set the
information
output direction
to SNMP
By default, switches of
master log in Fabric,
debugging and trap
information
synchronization are
turned on, so as log
and strap information
synchronization
switches in other
switches.
This configuration can
keep log information,
debugging information and
trap information in Fabric in
every switch synchronized.
4.5.3 Sending the Information to Loghost
To send configuration information to loghost, follow the steps below:
1) Enabling info-center
Perform the following operation in system view.
Table 4-20 Enable/disable info-center
Operation Command
Enable info-center info-center enable
Disable info-center undo info-center enable
 Note:
Info-center is enabled by default. After info-center is enabled, system performances are
affected when the system processes much information because of information
classification and outputting.
2) Configuring to output information to loghost
Perform the following operation in system view.