Operation Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 5 SNMP Configuration
Huawei Technologies Proprietary
5-6
Table 5-7 Set sysLocation
Operation Command
Set sysLocation
snmp-agent sys-info location
sysLocation
Restore the default location of the
Ethernet switch
undo snmp-agent sys-info location
By default, the sysLocation is specified as “Beijing China”.
5.3.7 Set SNMP Version
You can use the following commands to set the Set SNMP Version.
Perform the following configuration in system view.
Table 5-8 Set SNMP Version
Operation Command
Set SNMP Version
snmp-agent sys-info version { { v1 |
v2c | v3 } * | all }
Restore the default SNMP Version of the
Ethernet switch
undo snmp-agent sys-info version
{ { v1 | v2c | v3 } * | all }
5.3.8 Set the Engine ID of a Local or Remote Device
You can use the following commands to set the engine ID of a local or remote device.
Perform the following configuration in system view.
Table 5-9 Set the engine ID of a local or remote device
Operation Command
Set the engine ID of the device
snmp-agent local-engineid engineid
Restore the default engine ID of the
device.
undo snmp-agent local-engineid
By default, the engine ID is expressed as enterprise No. + device information. The
device information can be IP address, MAC address, or user-defined text.
5.3.9 Set/Delete an SNMP Group
You can use the following commands to set or delete an SNMP group.
Perform the following configuration in system view.