Operation Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-8
Severity Description
notifications The information should be concerned.
informational Common prompting information
debugging Debugging information
Notice: There is a slash between severity and digest.
6) Digest
The digest is abbreviation, it represent the abstract of contents.
Notice: There is a colon between digest and content.
7) Content
It is the contents of logging information.
4.5.2 Info-center Configuration
Switch supports 6 output directions of information.
The system assigns a channel in each output direction by default. See the table below.
Table 4-12 Numbers and names of the channels for log output
Output direction Channel number Default channel name
Console
0 console
Monitor
1 monitor
Info-center loghost
2 loghost
Trap buffer
3 trapbuffer
Logging buffer
4 logbuffer
snmp 5 snmpagent
Note:
The settings in the six directions are independent from each other. The settings will
take effect only after enabling the information center.
The info-center of Ethernet Switch has the following features:
z Support to output log in six directions, i.e., Console, monitor to Telnet terminal,
logbuffer, loghost, trapbuffer, and SNMP.
z The log is divided into 8 levels according to the significance and it can be filtered
based on the levels.