Operation Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-9
z The information can be classified in terms of the source modules and the
information can be filtered in accordance with the modules.
z The output language can be selected between Chinese and English.
2) Sending the Information to loghost.
Table 4-13 Sending the Information to loghost
Device Configuration Default value
Configuration
description
Enable info-center
By default,
info-center is
enabled.
Other configurations are
valid only if the info-center
is enabled.
Set the information
output direction to
loghost
-
The configuration about the
loghost on the switch and
that on loghost must be the
same; otherwise the
information cannot be sent
to the loghost correctly.
Switch
Set information
source
-
You can define which
modules and information to
be sent out and the
time-stamp format of
information, and so on. You
must turn on the switch of
the corresponding module
before defining output
debugging information.
Loghost
Refer to configuration
cases for related log
host configuration
- -
3) Sending the Information to the console terminal.