Operation Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-22
Table 4-34 Enabling/disabling info-center
Operation Command
Enable info-center info-center enable
Disable info-center undo info-center enable
 Note:
Info-center is enabled by default. After info-center is enabled, system performances are
affected when the system processes much information because of information
classification and outputting.
2) Configuring to output information to log buffer
Perform the following operation in system view.
Table 4-35 Configuring to output information to log buffer
Operation Command
Output information to log buffer
info-center logbuffer [ channel
{ channel-number | channel-name } ]
[ size buffersize ]
Cancel the configuration of outputting
information to log buffer
undo info-center logbuffer [ channel |
size ]
3) Configuring information source on the switch
By this configuration, you can define the information that sent to log buffer is generated
by which modules, information type, information level, and so on.
Perform the following operation in system view:
Table 4-36 Defining information source
Operation Command
Define information source
info-center source { modu-name | default } channel
{ channel-number | channel-name } [ { log | trap |
debug }* { level severity | state state }* ]
Cancel the configuration
of information source
undo info-center source { modu-name | default }
channel { channel-number | channel-name }
modu-name specifies the module name; default represents all the modules; level
refers to the severity levels; severity specifies the severity level of information. The