Operation Manual - System Management
Quidway S6500 Series Ethernet Switches Chapter 4 System Maintenance and Debugging
Huawei Technologies Proprietary
4-24
 Note:
Info-center is enabled by default. After info-center is enabled, system performances are
affected when the system processes much information because of information
classification and outputting.
2) Configuring to output information to trap buffer
Perform the following operation in system view.
Table 4-39 Configuring to output information to trap buffer
Operation Command
Output information to trap buffer
info-center trapbuffer [ size buffersize ]
[ channel { channel-number |
channel-name } ]
Cancel the configuration of outputting
information to trap buffer
undo info-center trapbuffer [ channel |
size ]
3) Configuring information source on the switch
By this configuration, you can define the information that sent to trap buffer is generated
by which modules, information type, information level, and so on.
Perform the following operation in system view:
Table 4-40 Defining information source
Operation Command
Define information source
info-center source { modu-name | default } channel
{ channel-number | channel-name } [ { log | trap |
debug }* { level severity | state state }* ]
Cancel the configuration
of information source
undo info-center source { modu-name | default }
channel { channel-number | channel-name }
modu-name specifies the module name; default represents all the modules; level
refers to the severity levels; severity specifies the severity level of information. The
information with the level below it will not be output. channel-number specifies the
channel number and channel-name specifies the channel name.
When defining the information sent to trap buffer, channel-number or channel-name
must be set to the channel that corresponds to Console direction.
Every channel has been set with a default record, whose module name is default and
the module number is 0xffff0000. However, for different channels, the default record

Table of Contents

Other manuals for Huawei Quidway S6500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei Quidway S6500 Series and is the answer not in the manual?

Huawei Quidway S6500 Series Specifications

General IconGeneral
BrandHuawei
ModelQuidway S6500 Series
CategoryNetwork Router
LanguageEnglish

Related product manuals