Table 70: FRU DC Power Requirements (continued)
Maximum Power RequirementModel NumberComponent
Control Board and Routing Engine (CB-RE)
150 W (Typical)
250 W at 55° C
250 W at 40° C
250 W at 25° C
RE-MX2000-1800X4CB-RE
400 WREMX2K-X8-64GCB-RE
MPCs
440 W at 55° C ambientMPC-3D-16XGE-SFPP16x10GE MPC
165 W
With MICs and optics:
239 W at 55° C
227 W at 40° C
219 W at 25° C
MX-MPC1-3D
MX-MPC1E-3D
MPC1
175 W
With MICs and optics:
249 W at 55° C
237 W at 40° C
228 W at 25° C
MX-MPC1-3D-Q
MX-MPC1E-3D-Q
MPC1 Q
274 W
With MICs and optics:
348 W at 55° C
329 W at 40° C
315 W at 25° C
MX-MPC2-3D
MX-MPC2E-3D
MPC2
195