Total RLDRAM 1036 MB
Total DDR DRAM 11264 MB
Start time: 2012-11-26 16:20:40 PST
Uptime: 18 hours, 15 minutes, 34 seconds
Max Power Consumption 610 Watts
Slot 18 information:
State Online
Temperature 31
Total CPU DRAM 2048 MB
Total RLDRAM 1324 MB
Total DDR DRAM 5120 MB
Start time: 2012-11-26 16:20:46 PST
Uptime: 18 hours, 15 minutes, 28 seconds
Max Power Consumption 440 Watts
RELATED DOCUMENTATION
MX2020 Craft Interface Description | 31
MX2020 Modular Port Concentrator (MPC) Description | 76
Maintaining MX2020 MPCs | 521
Replacing an MX2020 MPC and Adapter Card (ADC) | 536
Troubleshooting the MX2000 Router Power System
Problem
Description: The following alarms, LEDs, and other conditions indicate a problem with the AC or DC power
system:
•
If all AC or DC power supply modules (PSMs) have failed, the system temperature might have exceeded
the threshold, causing the system to shut down. See Step 9 for instructions on how to restart a
high-capacity AC or DC PSM after a shut down due to an over-temperature situation.
•
The yellow PWR OK LED blinks when an AC or a DC PSM is out of the power limit or is in an overcurrent
condition.
•
The red FAULT LED lights when the PSM is not receiving enough airflow to maintain the proper
temperature.
•
The red FAULT LED lights when the AC or DC output voltages are not within range.
•
The yellow INP0 LED blinks when the AC or DC voltage is present, but out of limits. This LED blinks
continuously for approximately a few seconds on and a few seconds off.
686