Figure 225: Installing an SFB
OK/FAIL
OK/FAIL
OK/FAIL
OK/FAIL
OK/FAIL
OK/FAIL
OK/FAIL
g007418
OK/FAIL
6. Check the LEDs on the SFB faceplate to verify that it is functioning normally.
•
The green OK/FAIL LED should light steadily a few minutes after the SFB is installed.
•
If the OK/FAIL LED is red, remove and install the SFB again. If the OK/FAIL LED still lights steadily,
the SFB is not functioning properly. Contact your customer support representative. See “Contacting
Customer Support” on page 705.
7. Check the status of the SFB by using the show chassis environment sfb command:
user@host> show chassis environment sfb
SFB 0 status:
State Online
Intake-Zone0 Temperature 32 degrees C / 89 degrees F
Exhaust-Zone1 Temperature 38 degrees C / 100 degrees F
IntakeA-Zone0 Temperature 28 degrees C / 82 degrees F
IntakeB-Zone1 Temperature 29 degrees C / 84 degrees F
Exhaust-Zone0 Temperature 31 degrees C / 87 degrees F
SFB-XF2-Zone1 Temperature 55 degrees C / 131 degrees F
SFB-XF1-Zone0 Temperature 48 degrees C / 118 degrees F
SFB-XF0-Zone0 Temperature 47 degrees C / 116 degrees F
Power
LTC3880-XF2-1.5v-RAIL 1500 mV
LTC3880-XF2-1.5v-CH0 1500 mV
LTC3880-XF2-1.5v-CH1 1500 mV
LTC3880-XF2-1.0v-RAIL 1029 mV
493