In this appendix:
Overview ................................................................................. C-1
Serial polling and SRQ .......................................................... C-14
Programming enable registers .............................................. C-14
Reading the registers ............................................................ C-15
Understanding bit settings ..................................................... C-16
Clearing registers .................................................................. C-17
Status model programming examples ................................... C-18
Overview
The status model consists of status register sets and queues. You can monitor the status model to
view instrument events and configure the status model to control the events.
As you work with the status model, be aware that the end result applies to the Status Byte Register.
All the status register sets and queues flow into the Status Byte Register. Your test program can read
this register to determine if a service request (SRQ) has occurred, and if so, which event caused it.
The Status Byte Register, register sets, and queues include:
Standard Event Register
Questionable Event Register
Operation Event Register
Output Queue
Error Queue
The relationship between the Status Byte Register, Standard Event Register, event queue, and
output queue is shown in the Non-programmable status registers diagram (on page C-2). The
relationship between the Status Byte Register, Questionable Event Register, and the Operation Event
Register is shown in the Programmable status registers diagram (on page C-6).
Appendix C
Status model

Table of Contents

Other manuals for Keithley 2461

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2461 and is the answer not in the manual?

Keithley 2461 Specifications

General IconGeneral
Maximum Current7 A
Power100 W
Resolution6.5 digits
Source Measure Unit (SMU)Yes
DC Voltage100 V
Maximum Voltage100 V
Display5-inch capacitive touchscreen
ConnectivityUSB, GPIB
SoftwareTSP
DC Current7 A
Current Source Range0 to 7 A
Voltage Measurement Range100 mV to 100 V
Current Measurement Range10 nA to 7 A
Voltage Measurement Resolution100 nV

Related product manuals