Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 183
Edge points along top of model not removed.
Part is rejected. (Min set to 85%.)
Edge points along top of model removed.
Part is accepted. (Min set to 85%.)
Removing edge points does not cause the edge detection algorithm to run again.
To change model senstivity:
1. In the Models list, select the model you want to configure by clicking on its selection control.

Table of Contents