Gocator Line Profile Sensors: User Manual
Gocator Device Files • 544
Element Type Description
@id 32s Measurement ID. Optional (measurement disabled if not
set).
Name String Measurement name.
Enabled Boolean
Measurement enable state:
0 – Disable
1 – Enable
HoldEnabled Boolean
Output hold enable state:
0 – Disable
1 – Enable
SmoothingEnabled Boolean
Smoothing enable state:
0 – Disable
1 – Enable
PreserveInvalidsEnabled Boolean Preserve invalid measurements enable state
0 – Disable
1 – Enable
SmoothingWindow 32u Smoothing window.
Scale 64f Output scaling factor.
Offset 64f Output offset factor.
DecisionMin 64f Minimum decision threshold.
DecisionMax 64f Maximum decision threshold.
Hole Tool Measurement
SurfaceOpening
A SurfaceOpening element defines settings for a surface opening tool and one or more of its
measurements.
Element Type Description
@isCustom Bool Reserved for future use.
@format 32s
Format type of the tool:
0 – Standard built-in tool
1 – GDK user-defined tool
2 – Internal GDK tool
@id
32s The tool's ID.
Name String Tool name.
Features
Collection Collection of geometric feature outputs available in the tool.
See SurfaceOpening above.
Source 32s Surface source.
SurfaceOpening Child Elements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2100 Series and is the answer not in the manual?

LMI Technologies Gocator 2100 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2100 Series
CategoryAccessories
LanguageEnglish

Related product manuals