EasyManuals Logo

LMI Technologies Gocator 2100 Series User Manual

LMI Technologies Gocator 2100 Series
800 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #96 background imageLoading...
Page #96 background image
Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 96
To remove a Buddy, click the "minus"icon next to the sensor you want to remove. To remove all
Buddies, click Remove All Buddies.
Over Temperature Protection
Sensors equipped with a 3B-N laser by default will turn off the laser if the temperature exceeds the safe
operating range. You can override the setting by disabling the overheat protection.
Disabling the setting is not recommended. Disabling the overheat protection feature could lead
to premature laser failure if the sensor operates outside the specified temperature range.
To enable/disable overheat temperature protection:
1. Check/uncheck the Over Temperature Shutoff option.
2. Save the job file.
Sensor Autostart
With the Autostart setting enabled, scanning and measurements begin automatically when the sensor
is powered on. Autostart must be enabled if the sensor will be used without being connected to a
computer.
To enable/disable Autostart:
1. Go to the Manage page and click on the Sensor System category.
2. Check/uncheck the Autostart option in the Main section.
Layout
The following sections describe the Layout category on the Manage page. This category lets you
configure dual- and multi-sensor systems.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2100 Series and is the answer not in the manual?

LMI Technologies Gocator 2100 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2100 Series
CategoryAccessories
LanguageEnglish

Related product manuals