Gocator Line Profile Sensors: User Manual
Gocator Device Files • 499
Element Type Description
2 – Valid
3 – Invalid
Conditions/AnyData
Element Type Description
Enabled Bool Indicates whether the condition is enabled.
RangeCountCase 32s
The case under which to record data:
0 – Range count at or above threshold of valid data points.
1 – Range count below threshold.
RangeCountThreshold 32u
The threshold for the number of range points that are valid.
Conditions/AnyData Elements
Conditions/Measurement
Element Type Description
Enabled Bool Indicates whether the condition is enabled.
Result 32s
The measurement decision criteria for the selected ID to be included in
the filter. Possible values are:
0 – Pass
1 – Fail
2 – Valid
3 – Invalid
Ids 32s The ID of the measurement to filter.
Conditions/Measurement Elements
Streams/Stream (Read-only)
Element Type Description
Step 32s
The data step of the stream being described. Possible values are:
1 – Video
2 – Range
3 – Surface
4 – Section
Id 32u The stream ID.
CadenceId 32u
Represents a stage in the data processing pipeline. The greater the
number, the farther removed from the initial acquisition stage. One of
the following:
0 – Primary
1 – Auxiliary
Streams/Stream Child Elements