Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 192
Circle Radius measurement running on profile extracted
from surface using defined section
You can configure the sampling distance between points along the section. Reducing the sampling
distance reduces the resolution of the profile, but increases the sensor’s performance and results in less
data being sent over the output.
Mininum spacing interval:highest profile resolution,
greater sensor CPUusage and data output