Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 352
Parameter Description
Averaging Width The width, in millimeters, of a window in which averaging of data points occurs. Use
this to compensate for noise around the section.
In the following, Averaging Width is set to 1.
When set to 0, only data points directly under that section are used in the profile.