Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 405
Measurement Illustration
Volume
Measures volume in XYZ space.
Area
Measures area in the XY plane.
Thickness
Measures thickness (height) of a part.
Measurements
Parameter Description
Source The sensor, or combination of sensors, that provides data
for the tool's measurements. For more information, see
Source on page 201.
Region The region to which the tool's measurements will apply. For
more information, see Regions on page 201.
Location
(Thickness measurement only)
One of the following:
l Max
l Min
l Average
l Median
l 2D Centroid (height of the centroid in the XY plane)
l 3D Centroid (height of the centroid in the XYZ space).
Filters The filters that are applied to measurement values before
they are output. For more information, see Filters on page
209.
Decision The Max and Min settings define the range that determines
whether the measurement tool sends a pass or fail decision
to the output. For more information, see Decisions on page
208.
Parameters

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2100 Series and is the answer not in the manual?

LMI Technologies Gocator 2100 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2100 Series
CategoryAccessories
LanguageEnglish

Related product manuals