Gocator Line Profile Sensors: User Manual
Gocator Web Interface • 442
To output measurement value or decision:
1. Go to the Output page.
2. Click on Analog in the Output panel.
3. Set Trigger Event to Measurement.
4. Select the measurement that should be used for output.
Only one measurement can be used for analog output. Measurements shown here correspond to
measurements that have been programmed using the Measurements page.
5. Specify Data Scale values.
The values specified here determine how measurement values are scaled to the minimum and
maximum current output. The Data Scale values are specified in millimeters for dimensional
measurements such as distance, square millimeters for areas, cubic millimeters for volumes, and
degrees for angle results.
6. Specify Current Range and Invalid current values.
The values specified here determine the minimum and maximum current values in milliamperes. If
Invalid is checked, the current value specified with the slider is used when a measurement value is not
valid. If Invalid is not checked, the output holds the last value when a measurement value is not valid.
7. Specify if the output is immediate or scheduled.
An analog output can become active immediately or scheduled. Check the Scheduled option if the
output needs to be scheduled.
A scheduled output becomes active after a specified delay from the start of Gocator exposure. A
scheduled output can be used to track the decisions for multiple objects as these objects travel from
the sensor to the eject gates. The delay specifies the distance from the sensor to the eject gates.
An Immediate output becomes active as soon as the measurement results are available. The output
activates after the Gocator finishes processing the data. As a result, the time between the start of

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LMI Technologies Gocator 2100 Series and is the answer not in the manual?

LMI Technologies Gocator 2100 Series Specifications

General IconGeneral
BrandLMI Technologies
ModelGocator 2100 Series
CategoryAccessories
LanguageEnglish

Related product manuals