EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Program 14: Trunk, Basic Setup; Basic Trunk Data Setup

NEC ELECTRA ELITE IPK II
617 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electra Elite IPK II Programming Manual 2 - 85
Program
14
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for
each trunk port. Refer to the chart below for a description of each option, its
range and default setting.
Program 14 : Trunk, Basic Setup
14-01 : Basic Trunk Data Setup
Level:
IN
Input Data
Trunk Port Number 001~200
Item
No.
Item Input Data Default
Related
Program
01
Trunk Name
Set the names for
trunks. The trunk
name displays at the
display of a multiline
terminal for incoming
and outgoing calls.
Up to 12
Characters
Line 001
Line 002
Line 003
:
Line 200
02
Transmit Level
Use this option to
select the CODEC
gain for the trunk. The
option sets the
amount of gain (signal
amplification) for the
trunk you are
programming.
1~63
(-15.5 ~ +15.5dB
in 0.5dB intervals)
32 (0dB)
03
Receive Level
Use this option to
select the CODEC
gain for the trunk. The
option sets the
amount of gain (signal
amplification) for the
trunk you are
programming.
1~63
(-15.5 ~ +15.5dB
in 0.5dB intervals)
32 (0dB)