2 - 396 Program 44 : ARS/F-Route Setup
Description
When Program 44-02-02 is set to type “3”, use Program 44-03 : Dial Analysis
Extension Table to set the dial extension analysis table. These tables are used when
the analyzed digits must be more than 8 digits. If the received digits do not match the
digits set in tables 1~250, table number 252 is used refer to the next Extension Table
Area (1~4) to be searched. If the received digits are not identified in tables 1~250, the
F-Route selection table number defined in table 251 is used.
The item numbers indicated below are different when using PCPro/WebPro due to the
window layout of the applications. Refer to the program within the PCPro/WebPro
application to determine the correct item number.
Program 44 : ARS/F-Route Setup
44-03 : Dial Analysis Extension Table
Level:
IN
Input Data
Extension Table Area Number 1~4
Dial Analysis Table Number 1~252
Dial Analysis Table Number : 1~250
Item
No.
Item Input Data Default
01
Dial
Up to 24 digits
Digits = 1~9, 0,
,
, #, @
(Press Line Key 1 for wild character @)
No Setting
02
ARS/F-Route Select
Table Number
0~500 (ARS/F-Route Table Number)
With Program 44-01 set to “0”, Program 44-05
is then checked.
With Program 44-01 set to “1”, Program 44-04
is then checked.
0