Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 219
Description
Use Program 21-13 : ISDN Calling Party Number Setup for Extensions to assign
each extension a Calling Party Number (maximum 16 digits per entry). The calling
number is the subscriber number of the dial-in number. When a call is made by an
extension which does not have an Extension Calling Number assigned (Program
21-12), the system sends the calling number for the ISDN trunk defined in Program
21-13.
If a Calling Party Number is assigned in both Programs 21-12 and 21-13, the system
sends the data in Program 21-13.
Conditions
None
Feature Cross Reference
J
ISDN Compatibility
Program 21 : Outgoing Call Setup
21-13 : ISDN Calling Party Number Setup for Extensions
Level:
IN
Input Data
Extension Number Maximum 8 digits
Item
No.
Calling Party
Number Data
Default
01 0~9,
,
, #
(Max. 16 digits)