EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Connecting System Settings

NEC ELECTRA ELITE IPK II
617 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Revision 1 Electra Elite IPK II
2 - 462 Program 50 : Common Channel Interoffice Signaling Service
Description
Use Program 50-02 : Connecting System Settings to define the settings for
each CCIS Route ID.
Program 50 : Common Channel Interoffice Signaling Service
50-02 : Connecting System Settings
Level:
IN
Input Data
CCIS Route ID Route ID 1~8: CCIS via DTI
Route ID 9: CCIS via IAD (IP-CCIS)
Item
No.
Item Description Input Data Default
01
Port Number of Common
Signaling Channel (DTI
only)
Specify the Trunk port to send D-channel information.
This program is available for using DTI package.
0~200 0
02
Common Signaling
Channel Data Speed
Assignment (DTI only)
Assign the baud rate of Common Signaling Channel
on DTI package.
0 = 64Kbps
1 = 56Kbps
2 = 48Kbps(1)
3 = 48Kbps (2)
1
03
Originating Point Code
(DTI only)
Assign the Point code of own side.
0~16367 0
04
Destination Point Code Assign the Point code of destination side on the DTI
link.
0~16367 0
05
Calling Name Indication Calling name indication will not send to destination
party if switch is turned to Disable.
0 = Disable
1 = Enable
1
06
CCH Channel Number on
the CCH Package
Assingnment
0~4 (0 = No
Setting)
0

Table of Contents

Other manuals for NEC ELECTRA ELITE IPK II

Related product manuals