Document Revision 1 Electra Elite IPK II
2 - 500 Program 81 : Basic Hardware Setup for Trunk
Description
Use Program 81-12 : Trunk Gain Level Data Setup to define the various initial data for
TLI/DTI/DID/BRT/PRT package.
Conditions
None
Feature Cross Reference
None
Program 81 : Basic Hardware Setup for Trunk
81-12 : Trunk Gain Level Data Setup
Level:
MF
Input Data
Trunk Number 1~200
Item
No.
Item Input Data Default
01
Internal Transmit Gain Level
0 = +2dB
1 = +4dB
2 = +6dB
3 = +8dB
4 = +12dB
5 = +16dB
6 = +3dB
7 = -3dB
8 = 0dB
3 = +8dB
02
Internal Receive Gain Level
3 = +8dB
03
External (tandem) Transmit Gain Level
8 = 0dB
04
External (tandem) Receive Gain Level
8 = 0dB