Description
Use Program 81-11 : Tie Line Initial Setup to define the various initial data for DID/
TLI/DTI packages.
Program 81 : Basic Hardware Setup for Trunk
81-11 : Tie Line Initial Setup
Level:
IN
Input Data
Trunk No. 1~ 200
Item
No.
Item Input Data Default
01
DP Interdigit Time Selection
The DP Interdigit Time is the minimum
pause time between dial pulses. Use this
Program to select either Pattern A or pattern
B.
0 = Pattern A
(Pattern A: 10pps - 650 ms,
20pps - 500 ms)
1 = Pattern B
(Pattern B: 10pps - 800 ms,
20pps - 800 ms)
1
02
Prepause Time Selection
Specifies the loop open time for a hookflash
signal sent to the Tie Line when the Recall
key on a multiline terminal is pressed. A
Single Line Telephone (SLT) generates a
hookflash to the Tie Line when a SLT
hookflash is assigned.
1~4
(1~4 = 0.5~2.0 seconds)
(5~15 = 3.0~13 seconds)
(0 = No Setting)
9
(600 ms)
03
Tie Line Answer Detect Time Selection
Specifies the time before an IPK II system
answer (Off-Hook) is recognized as an
answer.
0~15
(130 ms~1950 ms)
(0 = No Setting)
4
(520 ms)
04
Tie Line Release Detect Time Selection
Specifies the circuit disconnect detected on
the Tie Line on the distant system side is
recognized as Tie Line.
0~15
(130 ms~1950 ms)
(0 = No Setting)
4
(520 ms)
05
Incoming Signal Detect Time Selection
Specifies the time after the incoming signal
from another system is detected before the
acknowledge signal is sent out.
[Wink Start]
1~15
(130 ms~1950 ms)
(0 = No Setting)
[Delay]
1~15
(30 ms~450 ms)
(0 = No Setting)
[Wink Start]
3
(390 ms)
[Delay]
3
(90 ms)