Document Revision 1 Electra Elite IPK II
2 - 488 Program 80 : Basic Hardware Setup for System
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels
and timers for the Call Progress Tone Detector.
Tone Detector Type:
J
1 = Dial Tone for Trunk
J
2 = Busy Tone for Trunk
J
3 = Ring Back Tone for Trunk
J
4, 5 = Reserved
Program 80 : Basic Hardware Setup for System
80-04 : Call Progress Tone Detector Setup
Level:
IN
Input Data
Tone Detector Type No. 1 = Dial Tone for Trunk
2 = Busy Tone for Trunk
3 = Ring Back Tone for Trunk
4 = --- Reserve ---
5 = --- Reserve ---
Item No Item Input Data
04
No tone time
0~255 (30+30-7680ms)
05
Pulse Count
1~255
06
ON min. time
1~255 (30+30-7680ms)
07
ON max. time
0~255 (30+30-7680ms)
08
OFF min. time
1~255 (30+30-7680ms)
09
OFF max. time
0~255 (30+30-7680ms)
10
--- Reserve ---
0~8
11
--- Reserve ---
0~8