Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 505
Description
Program 82-08 : Sidetone Volume Setup allows adjust of the keyset sidetone volume.
There are two levels, based on whether the connected trunk is a digital trunk or
analog trunk.
Conditions
None
Feature Cross Reference
J
Central Office Calls, Answering
J
Central Office Calls, Placing
Program 82 : Basic Hardware Setup for Extension
82-08 : Sidetone Volume Setup
Level:
MF
Input Data
Item
No.
Description Input
Digital
Sidetone Level
Analog
Sidetone Level
01
Sidetone Volume
0 -54 (dB) -54 (dB)
1 -48 (dB) -54 (dB)
2 -42 (dB) -54 (dB)
3 -36 (dB) -48 (dB)
4 -30 (dB) -42 (dB)
5 -24 (dB) -36 (dB)
6 -18 (dB) -30 (dB)
7 -12 (dB) -24 (dB)
8 -12 (dB) -18 (dB)
9 -12 (dB) -12 (dB)