Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 553
Description
Use Program 90-13 : System Information Output to define the output port to be
used as the system information output. The baud rate for the COM port should be set
in Program 10-21-02.
Conditions
None
Feature Cross Reference
None
Program 90 : Maintenance Program
90-13 : System Information Output
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
Output Port Type
Indicate the type of connection used to print the
system information.
0 = No Setting
1 = COM port (CPUII)
2 = USB port (CPUII)
3 = LAN Port (CPUII)
4 = CTA/CTU
0
02
Destination Extension Number
If the output port type (item 1) is set to CTA,
enter the extension number with the CTA
connection.
Extension Number
(Up to 8 digits)
No Setting
03
Output Command
Dialing 1 from this program sends the system
report to the connected device.
Dial 1 + press HOLD
(Press HOLD key to cancel.)
-