Document Revision 1 Electra Elite IPK II
2 - 540 Program 90 : Maintenance Program
Description
(This program is available only via telephone programming and not through PC
Programming).
Use
Program 90-03 : Save Data to save the programmed data on the SRAM and Flash
ROM to the 16M/32M ATA removable Compact Flash memory card. This program
should be used after changing the programmed data.
Conditions
When reloading a customer database, the system must be reset (either using
Program 90-08 or power down/power up) before all uploaded programming will take
affect.
Feature Cross Reference
None
Program 90 : Maintenance Program
90-03 : Save Data
Level:
SA
Input Data
Item
No.
Item Input Data
01
Save Data
Dial 1 + press HOLD (Press HOLD to cancel.)