Document Revision 1 Electra Elite IPK II
2 - 190 Program 20 : System Option Setup
Description
Use Program 20-22 : System Options for Wireless DECT Service to define the
time the system waits before determining the Wireless DECT (DECT) phone is out of
range. For incoming calls, the timer begins when the call is received. If the time
defined here expires before the Wireless DECT phone starts to ring, the system
determines the phone is out of range and provides the out-of-range services
(indicates out-of range, transfers the call to voice mail or to another extension).
Conditions
None
Feature Cross Reference
J
Program 20 : System Option Setup
20-22 : System Options for Wireless DECT Service
Level:
IN
Input Data
Item
No.
Item Input Data Default
Related
Program
05
Out of Area Judging Time
0~64800 (sec) 8
06
Out of Area Talkie
0~48 0