Electra Elite IPK II Programming Manual 2 - 105
Program
15
Description
Use Program 15-01 : Basic Extension Data Setup to define the basic
settings for each extension.
The item numbers indicated below are different when using PCPro/WebPro.
Refer to the program within the PCPro/WebPro application to determine the
correct item number.
Program 15 : Extension, Basic Setup
15-01 : Basic Extension Data Setup
Level:
SA
Input Data
Extension Number Maximum 8 digits
Item
No.
Item Input Data Default
Related
Program
01
Extension Name
Define the extension/virtual
extension name.
Up to 12 Characters
02
Outgoing Trunk Line
Preference
Use this option to set the
extension’s outgoing Trunk
Line Preference. If enabled,
the extension user trunk dial
tone when they lift the handset.
The user hears trunk dial tone
only if allowed by Trunk Access
Map programming (Programs
14-07 and 15-06). Refer to the
Line Preference feature for
more details.
0=Off
1=On
0 14-06
21-02
03
SMDR Printout
Use this option to include or
exclude the extension in the
SMDR report.
0 = Do not print on
SMDR report
1 = Include on
SMDR report
1