Document Revision 1 Electra Elite IPK II
2 - 492 Program 81 : Basic Hardware Setup for Trunk
Description
Use Program 81-05 : ISDN BRI & PRI Layer 2 (T-Point) Initial Data Setup to define the
various basic data for layer 2 of ISDN BRI and PRI.
Conditions
None
Feature Cross Reference
None
Program 81 : Basic Hardware Setup for Trunk
81-05 : ISDN BRI & PRI Layer 2 (T-Point) Initial Data Setup
Level:
MF
Item
No.
Item Input Data Default
01
Timer T200
1~255 (100~25500 ms) 10 (1 sec)
02
Timer T201
1~255 (100~25500 ms) 10 (1 sec)
03
Timer T202
1~255 (100~25500 ms) 20 (2 sec)
04
Timer T203
1~255 (100~25500 ms) 250 (25 sec)
05
N200
1~255 3
06
N201
1~65535 (Byte) 260
07
N202
1~255 3