2 - 552 Program 90 : Maintenance Program
Description
Use Program 90-12 : System Alarm Output to set the options for the alarm report.
This program has 6 separate menu options. Define the output port to be used as the
output for system alarm report and set the system alarm options. The system can
have up to 50 reports.
Conditions
None
Feature Cross Reference
None
Program 90 : Maintenance Program
90-12 : System Alarm Output
Level:
IN
Input Data
Item
No.
Item Input Data Default
01
Output Port Type
Indicate the type of connection used for the System
Alarms. The baud rate for the COM port should be set in
Program 10-21-02.
0 = No Setting
1 = COM port (CPUII)
2 = USB port (CPUII)
3 = -- Reserve --
4 = CTA/CTU
0
02
Destination Extension Number
If the output port type (item 1) is set to CTA, enter the
extension number with the CTA connection.
Extension Number
(Up to 8 digits)
No
Setting
03
Output All Alarm Reports Print All? (Yes = 1)
-
04
Printout New Alarm Reports Print New? (Yes = 1)
-
05
Clear All Alarm Reports All Clear? (Yes = 1)
-
06
Output Mode 0 = Manual
1 = Auto
0