Document Revision 1 Electra Elite IPK II
2 - 478 Program 80 : Basic Hardware Setup for System
Default
Table 2-8 Basic Tones
Basic
Tone No.
Frequency (Hz)
Level
(dB)
Basic
Tone No.
Frequency (Hz) Level (dB)
01 400 - 13 17 520 / 650 -13 / -19
02 520 -13 18 650 / 780 -13 / -19
03 580 -13 19 780 / 1040 -13 / -19
04 660 -13 20 1040 -13
05 700 -13 21 -- Reserve -- -
06 800 -13 22 -- Reserve -- -
07 880 -13 23 -- Reserve -- -
08 1050 -13 24 -- Reserve -- -
09 350 / 440 -16 / -16 25 -- Reserve -- -
10 440 / 480 -16 / -16 26 -- Reserve -- -
11 480 / 620 -21 / -21 27 -- Reserve -- -
12 440 -16 28 -- Reserve -- -
13 -- Reserve -- - 29 -- Reserve -- -
14 520 / 650 -19 / -13 30 -- Reserve -- -
15 650 / 780 -19 / -13 31 -- Reserve -- -
16 780 / 1040 -19 / -13 32 -- Reserve -- -
Service
Tone
No.
Service Tone
Repeat
Count
Unit
Count
Basic
Tone No.
Duration
Gain Level
(dB)
1
No Tone
0 Basic 1 0 10 32 (0dB)
2
Intercom Dial Tone
0 Basic 1 9 10 32 (0dB)
3
Stutter Dial Tone
0Basic 6 0
9
0
9
0
9
2
1
1
1
1
77
32 (0dB)
4
Internal Recall Dial Tone
2Basic 2 9
0
1
1
32 (0dB)
32 (0dB)
5
Trunk Dial Tone
0 Basic 1 9 10 32 (0dB)