Document Revision 1 Electra Elite IPK II
2 - 198 Program 20 : System Option Setup
Description
Use Program 20-31 : Timer Class Timer Assignment to assign values to the timers
on a class of service basis.
Program 20 : System Option Setup
20-31 : Timer Class Timer Assignment
Level:
IN
Input Data
Item
No.
Item Input Data Default
Related
Programming
01
Trunk Queuing Callback Duration Time
0~64800 seconds
15 seconds 20-01-08
02
Callback / Trunk Queuing Cancel Time
0~64800 seconds
64800 seconds 20-01-09
03
CAR/SIE/Virtual Extension Delay Interval
0~64800 seconds
10 seconds 20-04-03
04
Intercom Inter-digits Time (Intercom I/D
Timer)
0~64800 seconds
10 seconds 21-01-02
05
Trunk Inter-digits Time (Trunk I/D Timer)
0~64800 seconds
5 seconds 21-01-03
06
Hotline Time Start Time (Hotline Start)
0~64800 seconds
5 seconds 21-01-09
07
Ring No Answer Alarm Time
0~64800 seconds
60 seconds 22-01-02
08
DIL/Incoming Ring Group No Answer Time
0~64800 seconds
0 seconds 22-01-04
09
DID Ring-No-Answer Time
0~64800 seconds
20 seconds 22-01-06
10
Hold Recall Time (Non Exclusive Hold)
0~64800 seconds
90 seconds 24-01-01
11
Hold Recall CallBack Time (Non Exclusive
Hold)
0~64800 seconds
30 seconds 24-01-02
12
Exclusive Hold Recall Time
0~64800 seconds
90 seconds 24-01-03
13
Exclusive Hold Recall Callback Time
0~64800 seconds
30 seconds 24-01-04
14
Park Hold Time – Normal
0~64800 seconds
90 seconds 24-01-06
15
Delayed Call Forwarding Time (Call Forward
No Answer)
0~64800 seconds
10 seconds 24-02-03
16
Transfer Recall Time
0~64800 seconds
30 seconds 24-02-04
17
DID/DISA No Answer Time (Disconnect or
IRG or VM)
0~64800 seconds
30 seconds 25-07-02
18
Disconnect after Re-transfer to IRG
0~64800 seconds
60 seconds 25-07-03