Document Revision 1 Electra Elite IPK II
2 - 184 Program 20 : System Option Setup
Description
Use Program 20-17 : Operator’s Extension to designate an operator. When an
extension user dials “0” or “9” (defined by Program 11-01 Type 5), calls go to the
operator selected in this program.
If you do not assign an extension in Program 90-11-01, system alarms appear on the
extension assigned in this option.
Conditions
None
Feature Cross Reference
J
Intercom
Program 20 : System Option Setup
20-17 : Operator’s Extension
Level:
IN
Input Data
Operator Number 1~8
Item
No.
Item Input Data Default
Related
Program
01
Operator’s Extension Number
Define the extension numbers which are
to be used as operators.
Up to 8 digits
101 11-01
20-01-01