Document Revision 1 Electra Elite IPK II
2 - 516 Program 84 : Hardware Setup for VoIP
Description
Use Program 84-06 : VoIP Info to set up threshold levels of the MG16 ETU.
Program 84 : Hardware Setup for VoIP
84-06 : VoIP Info
Level:
IN
Input Data
Slot Number 01~24
Item
No.
Item Input Data Default Description
01
RTP Port Number
0~65535 10020
02
RTCP Port Number
RTP Port Number + 1 10021
It has to be RTP Port Number
+ 1.
03
--- Not Used ---
04
Fract lost Threshold
0~4294967295 ms 0
The data will be sent to the
CPUII if the value exceeds
the defined value.
05
Packets Lost
Threshold
0~4294967295 0
The data will be sent to the
CPUII if the value exceeds
the defined value.
06
Ext High Sequence
Threshold
0~4294967295 0
The data will be sent to the
CPUII if the value exceeds
the defined value.
07
Jitter Threshold
0~4294967295 (sec) 0
The data will be sent to the
CPUII if the value exceeds
the defined value.
08
Last LSR Threshold
0~4294967295 0
The data will be sent to the
CPUII if the value exceeds
the defined value.
09
Delay LSR Threshold
0~4294967295 0
The data will be sent to the
CPUII if the value exceeds
the defined value.