Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 147
Description
Use Program 16-03 : Secondary Department Group to set a second Department
Group for extensions. Up to 16 extensions can be assigned per a Department Group.
There are 64 Department Groups available.
Default
H
All extension groups : No setting
Conditions
None
Feature Cross Reference
J
Department Calling
Program 16 : Department Group Setup
16-03 : Secondary Department Group
Level:
IN
Input Data
Department (Extension) Group Number 01~64
Item
No.
Secondary
Extension
Number
Extension
Number
Priority
Order
Description
01 1~16 Maximum 8
digits
0~999 This program is set up when placing
telephones into two or more groups.