EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - DIL Assignment

NEC ELECTRA ELITE IPK II
617 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 233
Description
Use Program 22-07 : DIL Assignment to assign the destination extension or
Department Calling Group for each DIL Incoming trunk. A DIL rings an extension
directly, without any other Access Map or Ring Group programming. If an extension
has a line key, the DIL rings the line key. If the extension does not have a line key, the
DIL rings CAP keys. Use Program 22-02 to designate a trunk as a DIL). You can
make eight DIL assignments, one for each Night Service mode.
Conditions
H
Program 22-02 must be set to ‘4’ for the trunk.
Feature Cross Reference
J
Direct Inward Line (DIL)
Program 22 : Incoming Call Setup
22-07 : DIL Assignment
Level:
IN
Input Data
Trunk Port Number 001~200
Item
No.
Day/Night
Mode
Number of Transferring
Destination
Default
01 1~8 Extension Number (maximum 8
digits)
Pilot Number
No Setting

Table of Contents