Electra Elite IPK II Programming Manual 3 - 337
Program
35
Description
Use Program 35-01 : SMDR Options to set the SMDR (Station Message
Detail Recording) options for each of the eight SMDR ports. Refer to the
following chart for a description of each option, its range and default setting.
Program 35 : SMDR Account Code Setup
35-01 : SMDR Options
Level:
IN
Input Data
SMDR Port Number 1~8
Item
No.
Item Input Data Default
01
Output Port Type
This option specifies the type of connection
used for SMDR. The baud rate for the COM port
should be set in Program 10-21-02 or 15-02-19.
0 = None
1 = COM (CPUII)
3 = LAN
4 = CTA/CTU
0
02
Output Destination Number
This option specifies the SMDR printer output
extension (CTA/CTU extension number).
Up to 8 digits No
Setting
03
Header Language
Specify the language in which the SMDR
header should be printed.
0 = English
1=German
2 = French
3=Italian
4 = Spanish
0
04
Omit Digits
The number of digits entered in this option do
not print on the SMDR report. For example, if
the entry is 10, the first 10 digits a user dials do
not appear on the SMDR report.
0~24
(0 = Not applied)
0
05
Minimum Digits
Outgoing calls must be at least this number of
digits for inclusion in the SMDR report.
0~24
(0 = Not Applied)
0
06
Minimum Call Duration
The duration of the call must be at least this
interval to be included on the SMDR report.
0~65535 (sec)
(0 = All)
0