EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - Class of Service Options (Supplementary Service)

NEC ELECTRA ELITE IPK II
617 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Revision 1 Electra Elite IPK II
2 - 172 Program 20 : System Option Setup
Description
Use Program 20-13 : Class of Service Options (Supplementary Service) to define
the supplementary feature availability for each extension Class of Service (COS).
Program 20 : System Option Setup
20-13 : Class of Service Options (Supplementary Service)
Level:
IN
Input Data
Class of Service Number 01~15
Item
No.
Item Input Data
Default
Related
Programming
COS
01~14
COS
15
01
Long Conversation Alarm
Turns off or on the Warning Tone for Long Conversation
(not for single line telephones).
0 = Off
1 = On
00
02
Long Conversation Cutoff (Incoming)
Turns off or on an extension to use Long Conversation
Cutoff for incoming calls.
0 = Off
1 = On
00
03
Long Conversation Cutoff (Outgoing)
Turns off or on an extension to use Long Conversation
Cutoff for outgoing calls.
0 = Off
1 = On
00
04
Call Forward/DND Override (Bypass Call)
Turns off or on an extension to use Call Forwarding/
DND Override.
0 = Off
1 = On
11
05
Intercom Off-Hook Signaling
Turns off or on an extension’s ability to receive Off-Hook
signals.
0 = Off
1 = On
11
06
Automatic Off Hook Signaling (Automatic Override)
Allows a busy extension’s ability to manually (0) or
automatically (1) receive off-hook signals.
0 = Off
1 = On
11
07
Message Waiting
Turns off or on an extension’s ability to leave Message
Waiting.
0 = Off
1 = On
11