Document Revision 1 Electra Elite IPK II
2 - 118 Program 15 : Extension, Basic Setup
Description
Use Program 15-07 : Programmable Function Keys to assign functions to a
multiline terminal's line keys.
For certain functions, you can append data to the key’s basic function. For example,
the function 26 appended by data 1 makes a Group Call Pickup key for Pickup Group
1. You can also program Function Keys using Service Codes.
In order to clear any previously programmed key, press 000 to erase any displayed
code.
Program 15 : Extension, Basic Setup
15-07 : Programmable Function Keys
Level:
SA
Input Data
Extension Number Maximum 8 digits
Item
No.
Line Key
Number
Function Number Additional Data
01 1~48 0~99
(Normal Function Code) (Service Code 751 by
default)
* 00-* 99
(Appearance Function Code) (Service Code 752 by
default)
Refer to Function