Electra Elite IPK II Programming Manual 2 - 325
Program
34
Description
Use Program 34-01 : E&M Tie Line Basic Setup to defines the basic settings
for each E&M Tie line.
Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
Level:
IN
Input Data
Trunk Port Number 001~200
Item
No.
Item Input Data Default Description
Related
Program
01
DID/E&M Start
Signaling
0=2
nd
dial tone
1=Wink
2 = Immediate
3=Delay
1
Set the start signaling mode for
DID and tie trunks. DID and tie
trunks can use either
immediate start or wink start
signaling.
22-02
02
--- Not Used ---
03
E&M Dial-In Mode
0 = Specify Extension
Number (Intercom)
1 = Use conversion
table (NTT)
0
Determine if the incoming Tie
Line call should be directed as
an intercom call or if it should
follow the DID Translation
Table in Program 22-11.
22-11
04
E&M Line Dial Tone 0 = Disable (No)
1 = Enable (Yes)
1
Enter 1 if the Tie Line should
send dial tone to the calling
system once the call is set up.
Enter 0 if the Tie Line should
not send dial tone.
05
System Toll
Restriction
0=No
1=Yes
0
Determine if an incoming Tie
Line call should be subject to
Toll Restriction.