Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 207
Description
Use Program 21-05 : Toll Restriction Class to set the system Toll Restriction classes
(1~15).
Program 21 : Outgoing Call Setup
21-05 : Toll Restriction Class
Level:
IN
Input Data
Toll Restriction Class Number 1~15
Item
No.
Item Input Data Default Description
Related
Program
01
International Call
Restriction Table
0 = Unassigned
(No)
1 = Assigned
(Yes)
1
This option assigns/unassigns the
International Call Restrict Table
for the Toll Restriction Class you
are programming. Enter
International Call Restrict Table
data in Program 21-06-01.
21-06-01
02
International Call
Permit Code Table
0 = Unassigned
(No)
1 = Assigned
(Yes)
1
This option assigns/unassigns the
International Call Permit Table for
the Toll Restriction Class you are
programming. Enter International
Call Permit Table data in Program
21-06-02.
21-06-02
03
-- Not Used --
04
Maximum Number of
Digits Table
Assignment
1~4 = Table
0 =Disable
(None)
0
Select the table (defined in
21-06-03) to be used to determine
the maximum number of digits
allowed for outgoing calls.
21-06-03
05
Common Permit
Code Table
0 = Unassigned
(No)
1 = Assigned
(Yes)
0
It chooses whether the table set
up by 21-06-04 is referred to, or
not referred to.
21-06-04
06
Common Restriction
Table
0 = Unassigned
(No)
1 = Assigned
(Yes)
0
It chooses whether the table set
up by 21-06-05 is referred to, or
not referred to.
21-06-05
07
Permit Code Table
1~4 = Table
0 = Disable
(None)
0
Set the tables 1~4 when referring
to the table set up by 21-06-06.
21-06-06

Table of Contents