Document Revision 1 Electra Elite IPK II
2 - 388 Program 42 : Hotel Setup
Description
Use Program 42-02 : Hotel/Motel Telephone Setup to define the basic operation of the
Hotel/Motel extensions.
Conditions
None
Feature Cross Reference
J
Hotel/Motel
Program 42 : Hotel Setup
42-02 : Hotel/Motel Telephone Setup
Level:
IN
Input Data
Extension Number Up to 8 digits
Item No. Item Input Data Default
01
Hotel Mode
If you want an extension to operate in the Hotel/
Motel mode, enter 1. If you want the telephone
to operate in the business mode, enter 0.
0 = Normal
1 = Hotel
0
02
Toll Restriction Class When Check In
Assign an extension’s Toll Restriction Class
when it is checked in. The system has 15 Toll
Restriction Classes (1~15). The entry you
make in this option affects the telephone in all
Night Service modes. (Refer to Programs 21-05
and 21-06 to set up the Toll Restriction dialing
options.) When the extension is checked out, it
uses the Toll Restriction Class set in Program
21-04.
1~15 1