Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 533
Description
Use Program 85-04 : Port Mirroring Setup to define the port mirroring for each HUB(8)
ETU. This permits traffic from one port to be simultaneously transmitted to a second
port. Port mirroring is typically used for debugging with a protocol analyzer.
Conditions
H
Set to the port where the protocol analyzer is connected.
Feature Cross Reference
J
Voice Over Internet Protocol (VoIP)
Program 85 : HUB(8) LAN Setup
85-04 : Port Mirroring Setup
Level:
IN
Input Data
Hub Slot 1~24
Item
No.
Item Input Data Default Description
01
Port Mirroring
0 = Disable
1 = Enable
0
02
Source Port
1~8 1 Set to the port to be
monitored.
03
Target Port
1~8 1 Set to the port where
the protocol analyzer
is connected.