EasyManua.ls Logo

NEC ELECTRA ELITE IPK II - General Purpose Relay Setup

NEC ELECTRA ELITE IPK II
617 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Document Revision 1 Electra Elite IPK II
2 - 14 Program 10 : System Configuration Setup
Description
Use Program 10-05 : General Purpose Relay Setup to define which Relay circuits
(5~8) on PGD(2)-U10 Adapter are used for General Purpose Relay.
Input Data
- INDEX-1 -
Conditions
None
Feature Cross Reference
J
Analog Communications Interface (ACI)
Program 10 : System Configuration Setup
10-05 : General Purpose Relay Setup
Level:
IN
General Purpose Relay No. 1~8
Item
No.
Item Input Data Default
01
Slot No.
Physical Port of ESIU
Sensor circuit No.
Slot No: 0~16
ESIU Port: 0~16
Relay No: 0, 5~8
After each entry,
pressing the
Transfer Key will
advance to the
next entry.
0 - 0 - 0