Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 7
For SLI PKG Setup
04
Optional Installed Unit 1
0=None
1=APR Module
2 = APA Module
3=ADA Module
4 = CTA/CTU Module
0
05
Optional Installed Unit 2
0=None
1=APR Module
2 = APA Module
3=ADA Module
4 = CTA/CTU Module
0
B-Channel 2
Item
No.
Item Input Data Default
06
Terminal Type (B2)
0 = Not set
6 = PGD (Paging)
7 = PGD (Tone Ringer)
8 = PGD (Door Box)
9=PGD (ACI)
12 = APR
0
07
Logical Port Number (B2)
PGD (Paging/Tone Ringer) = 1-PGmax
PGD (for Door Box) = 1-DBmax
PGD (Analog I/F) = 1-ACImax
APR (for B2 mode) 193~256
Physical Port Number 01~08
Item
No.
Item Input Data Default
01
Logical Port Number
0~256 0
02
--- Not Used ---
03
Transmit Gain Level (S-Level)
1~63 (-15.5 +15.5dB) 32 (0dB)
04
Receive Gain Level (R-Level)
1~63 (-15.5 +15.5dB) 32 (0dB)
Item
No.
Item Input Data Default