Document Revision 1 Electra Elite IPK II
2 - 486 Program 80 : Basic Hardware Setup for System
Item
No
Item Input Data
01
Detect Level
0 = 0dBm ~ -25dBm
1 = -5dBm ~ -30dBm
2 = -10dBm ~ -35dBm
3 = -15dBm ~ -40dBm
4 = -20dBm ~ -45dBm
5 = -25dBm ~ -50dBm
6 = -30dBm ~ -55dBm
02
Start delay time
0~255 (0.25 ms ~ 64 ms)
03
Min. detect level
0~15
detect level 0 : –10dBm(0) to –25dBm(15)
detect level 1 : –15dBm(0) to –30dBm(15)
detect level 2 : –20dBm(0) to –35dBm(15)
detect level 3 : –25dBm(0) to –40dBm(15)
detect level 4 : –30dBm(0) to –45dBm(15)
detect level 5 : –35dBm(0) to –50dBm(15)
detect level 6 : –40dBm(0) to –55dBm(15)
04
Max. detect level
0~15
detect level 0 : 0dBm(0) to –15dBm(15)
detect level 1 : –5dBm(0) to –20dBm(15)
detect level 2 : –10dBm(0) to –25dBm(15)
detect level 3 : –15dBm(0) to –30dBm(15)
detect level 4 : –20dBm(0) to –35dBm(15)
detect level 5 : –25dBm(0) to –40dBm(15)
detect level 6 : –30dBm(0) to –45dBm(15)
05
Forward twist level
0~9 (1dB ~ 10dB)
06
Backward twist level
0~9 (1dB ~ 10dB)
07
ON detect time
1~255 (15+ 15 ms ~ 3825 ms)
08
OFF detect time
1-255 (15+ 15 ms ~ 3825 ms)